Fire pump room layout

Identify the components of a fire pump and driver. Describe the purpose of the various components of a fire pump and driver. Discuss the variables that impact the layout of a fire pump and how they are addressed. An important part of the standard is that “Location and access to the fire pump room shall be pre-planned with the fire department. Fire and Security Consulting Services (FSCS) is frequently consulted on the design requirements for fire pump rooms.


While NFPA requires that access to the fire pump room be pre-planned with the fire department, it now requires that the location of the fire pump room also be pre-planned.

Fire Pump Room Schematic - as PDF File (.pdf), Text File (.txt) or view presentation slides online. Following are some code requirements for fire pumps that you should factor into pump selection and system design. Horizontal elbows or tees upstream of a fire pump must be pipe diameters from the suction flange on a split-case fire pump. Pumps must maintain a positive suction pressure at the suction flange.


PUMP ROOM LAYOUT CAD drawing. This CAD file includes detail plan and sections. FIRE PUMPS DESIGN AND CONSTRUCTION STANDARD 1. Our CAD block library is regularly updated.

Upon completion of the pump and sprinkler piping installation, a field acceptance test shall be conducted at minimum, rate and peak loads of the fire pump by controlling the quantity of water discharged through approved test devices. Free Shipping on Orders Over $150! Quality Professional Equipment. Nonetheless, this room made very efficient use of the space given, and the equipment was installed in a way that will allow for future servicing with minimal trouble.


Typically future servicing of equipment is not often a high priority when the layout of a pump room is planned. The ABCs of Fire Pump Installations. As projects become larger and more complex, such as those found in campus settings, installation requirements vary and design options increase, which often leads to confusion on the electrical design front. A fire pump controller must start the fire pump in response to an external starting signal which is normally pressure-setting of a pressure switch plumbed into piping works. Once starte the engine must continue to run until it is manually stopped or runs out of fuel.


As per the NFPA 2 section 4. Hazardous material information that includes: location and quantity of hazardous material. Consequently, if the fire pump at the lowest level fails, the rest of the fire pumps in series will also fail for lack of adequate suction pressure. Under the new NFPA provisions, fire pumps in series must be installed in the same pump room. This modified fire pump design increases the reliability of the overall fire pump operation.


Where a fire pump is not required for the automatic sprinkler systems, a manual standpipe is acceptable. Fire Pumps shall be provided when water supplies are shown to be inadequate. Fire pump systems shall be designed in accordance with NFPA 20.