Tuesday, February 5, 2019

Pipe support calculation xls

Piping Design Info XLS is an excel file which almost contains all sizes of various fittings and structure sizes. This came out handy at many calculations which we requires from time to time while doing piping. The workbook can be used to calculate the weight of the pipe , flanges, fittings, insulation and hydrotest water for a single size or for multi-size configurations. For Hydrotest water add the lineal footage of the pipe plus add in a factor for the fittings and valves. The pipe support spread sheet PIPESUPPORT.


Pulsating lines: Spans indicated above shall not be used.

All dimensions are in millimeters, except as noted. Notes Tempratures in the above table are in degrees Celsius, as indicated (maximum 4°C) 1To 315°C 3To 400°C of 12. Document design calculations for pipe support referenced in calculations title. OR1ONiAL This calculation verifies pipe support. Adding Calculator Angles Bolts Brace Formulas Channels ELL.


W Shapes W Tees Weights Weld-o-Lets Weld-o. When buried pipe is installed on supports , it is usually because of unstable ground condi-tions. There shoul in most cases, be no vehicle loading.

Pipe Spans Pipe Tables Rt. ASME has suggested the standards for support span, but the bending stress considered in its calculation is very low (1 Mpa). There are other references also who have listed the maximum support span. How do you calculate how much load a particular pipe support can take?


Each pipe support has its own load carrying capacities depending upon its function. Factor for modifying stress value obtained by the basic formula for S fs = 1. Exterior and interior diameters, and thickness of different pipe materials. Computer codes used in piping analysis are identified in this section with a brief description of each. Analysis boundaries, decoupling criteria and other modeling requirements are presented. A complete set of piping drawings.


For designing a pipe support (random on platform or additional field support ) structural engineer requests for LOADS for the piping system. Its the responsibility of the piping designer to provide with the loads unless there is a provision in the project guidelines that loads will be calculated by the structural engineer himself. The calculated bending stress is within limits. Calculation of Fluid Flow Rate, Q, for given frictional head loss, hL, pipe diam.


Instructions: Enter values in blue boxes. The load includes the weight of the pipe , the content that the pipe carries, all the pipe fittings attached to pipe , and the pipe covering such as insulation. Here’s a look at some of the fundamentals, and good resources for.

The passive soil resistance varies depending on the soil type and the degree of compaction of the pipe zone backfill material, native soil characteristics, cover depth and trench width. Spans are based on using carbon steel pipe (A53-GR.B) filled with water.